Log in

View Full Version : Std 102 water ballast plug


Tom Dukerich
April 10th 05, 07:27 PM
The plug for the water ballast is stuck in up position. I've reached
in and tried to operate the lever by hand, but it will not move. Any
suggestions for getting it operational?

Thanks - Tom

John Sinclair
April 10th 05, 09:35 PM
Penetrating oil, inside and out + heat gun applied
to valve. Work it gently until it starts to move.
JJ

At 19:00 10 April 2005, Tom Dukerich wrote:
>The plug for the water ballast is stuck in up position.
> I've reached
>in and tried to operate the lever by hand, but it will
>not move. Any
>suggestions for getting it operational?
>
>Thanks - Tom
>

April 12th 05, 01:42 AM
were the wing to fuselage linkages in the right position when the wings
were
put on the fuselage - if the dump valve was closed in the wing and the
dump
lever in the fuselage was open - you must take the wings off and put
everything
"closed" and reassemble.

Tom Dukerich
April 12th 05, 05:10 PM
There are no valves in the wings. They both feed to a drain plug in the
fuselage belly.

On Mon, 11 Apr 2005 17:42:13 -0700, rhwoody wrote:

> were the wing to fuselage linkages in the right position when the wings
> were
> put on the fuselage - if the dump valve was closed in the wing and the
> dump
> lever in the fuselage was open - you must take the wings off and put
> everything
> "closed" and reassemble.